Hardware_Model_Power.csv
If you are using the Technology Intelligence Platform version of IT Visibility’s export, information in this section is not applicable to you. Instead, see IT Visibility Data Export Using Technology Intelligence Platform. To check whether you are using Technology Intelligence Platform or Pre-Technology Intelligence Platform version, go to the Data Export page ( IT Visibility > Data Exports ). If you see two buttons for exporting—a Create Export button and a Create Export (Beta) button—you are using a Pre-Technology Intelligence Platform version (export version 1 or version 2). If you only see the Create Export button, you are either on the Technology Intelligence Platform version or export version 3. For related information, see Upgrading to the Export Version 3 of IT Visibility.
This file contains hardware model power information.
| Column Position | Column Name | Type | Column Description |
|---|---|---|---|
| 1 | HardwareModelPowerID | UUID | The unique identifier for hardware model power. |
| 2 | HardwareModelID | UUID | The HardwareModelID in Technopedia this Hardware Model Power record relates to. |
| 3 | ACCurrentHighMin | Float | Manufacturer's suggested AC electrical input requirements: The minimum current when the voltage switch is turned on to the high range setting. |
| 4 | ACCurrentHighMax | Float | Manufacturer's suggested AC electrical input requirements: The maximum current when the voltage switch is turned on the high range setting. |
| 5 | ACCurrentLowMin | Float | Manufacturer's suggested AC electrical input requirements: The minimum current when the voltage switch is turned on to the low range setting, or when the device has no voltage switch (single voltage range). |
| 6 | ACCurrentLowMax | Float | Manufacturer's suggested AC electrical input requirements: The maximum current when the voltage switch is turned on to the low range setting, or when the device has no voltage switch (single voltage range). |
| 7 | ACFrequencyMin | Float | The manufacturer's suggested AC input requirements: The minimum frequency (whether the voltage switch is turned on low/high or when the device has no voltage switch). |
| 8 | ACFrequencyMax | Float | The manufacturer's suggested AC input requirements: The maximum frequency (whether the voltage switch is turned on low/high or when the device has no voltage switch). |
| 9 | ACHeatDissipationAverage | String | The average amount of heat per-unit of time generated by the device during typical use when it is hooked up to AC power (in BTU/hr). |
| 10 | ACHeatDissipationMax | String | The peak or maximum amount of heat per-units of time generated by the device during typical usage when it is hooked up to AC power (in BTU/hr). |
| 11 | ACPhase | Int64 | The phase of the AC. |
| 12 | AcPowerAverage | String | The average amount of power (energy per-unit of time) consumed by the device during typical use when it is hooked up to AC power (in watt or volt-amp). |
| 13 | ACPowerAverageUnit | String | The unit for AC_POWER_AVG column (watt or volt-amp). |
| 14 | ACPowerMax | String | The peak or maximum amount of power (energy per-unit of time) consumed by the device when it is hooked up to AC power (in watt or volt-amp). |
| 15 | ACPowerMaxUnit | String | The unit for the AC_POWER_MAX column (watt or volt-amp). |
| 16 | ACVoltageHighMin | Float | Manufacturer's suggested AC electrical input requirements: The minimum voltage when the voltage switch is turned to on the high range setting. |
| 17 | ACVoltageHighMax | Float | Manufacturer's suggested AC electrical input requirements: The maximum voltage when the voltage switch is turned on to the high range setting. |
| 18 | ACVoltageLowMin | Float | Manufacturer's suggested AC electrical input requirements: The minimum voltage when the voltage switch is turned on to the low range setting, or when the device has no voltage switch (single voltage range). |
| 19 | ACVoltageLowMax | Float | Manufacturer's suggested AC electrical input requirements: The maximum voltage when the voltage switch is turned on to the low range setting, or when the device has no voltage switch (single voltage range) . |
| 20 | BatteryLife | Int64 | Hours of possible battery life. |
| 21 | BatteryType | String | Battery type. |
| 22 | DCCurrentLow | Float | The manufacturer's suggested DC input requirements: The current when the voltage switch is turned on the low setting or when the device has no voltage switch (single voltage). |
| 23 | DCCurrentHigh | Float | The manufacturer's suggested DC input requirements: The current when the voltage switch is turned on the high setting. |
| 24 | DCHeatDissipationAverage | String | The average amount of heat per-unit of time generated by the device during typical use when it is hooked up to DC power (in BTU/hr). |
| 25 | DCHeatDissipationMax | String | The peak or maximum amount of heat per-unit of time generated by the device when it is hooked up to DC power (in BTU/hr). |
| 26 | DCPowerAverage | String | The average amount of power (energy per-unit of time) consumed by the device during typical use when it is hooked up. |
| 27 | DCPowerMax | String | The peak or maximum amount of power (energy per-unit of time) consumed by the device when it is hooked up to DC power (in watt or volt-amp). |
| 28 | DCVoltageLow | Float | The manufacturer's suggested DC input requirements: The voltage when the voltage switch is turned on the low setting or when the device has no voltage switch (single voltage). |
| 29 | DCVoltageHigh | Float | The manufacturer's suggested DC input requirement: The voltage when the voltage switch is turned on the high setting. |
| 30 | EmergencyPower | String | Listing of the emergency power. |
| 31 | Epeat | String | This is a flag to indicate which EPEAT certification the device has earned: Gold, Silver, or Bronze. |
| 32 | HasDedicatedCircuit | String | Listing of the dedicated circuit. |
| 33 | IsEnergyStar | String | This is a flag to indicate whether the device has earned the Energy Star certification or not. |
| 34 | NonOperatingHumidityMin | Float | The manufacturer's suggested minimum humidity (percentage) of the device when it is non-operational or in storage. |
| 35 | NonOperatingHumidityMax | Float | The manufacturer's suggested peak or maximum humidity (percentage) of the device when it is non-operational or in storage. |
| 36 | NonOperatingTemperatureMin | Float | The manufacturer's suggested minimum temperature of the device when it is non-operational or in storage (in Fahrenheit). |
| 37 | NonOperatingTemperatureMax | Float | The manufacturer's suggested peak or maximum temperature of the device when it is non-operational or in storage (in Fahrenheit). |
| 38 | OperatingHumidityMin | Float | The manufacturer's suggested minimum humidity (percentage) of the device during operation. |
| 39 | OperatingHumidityMax | Float | The manufacturer's suggested peak or maximum humidity (percentage) of the device during operation. |
| 40 | OperatingTemperatureMin | Float | The manufacturer's suggested minimum temperature of the device during operation (in Fahrenheit). |
| 41 | OperatingTemperatureMax | Float | The manufacturer's suggested peak or maximum temperature of the device during operation (in Fahrenheit). |
| 42 | PlugType | String | Plug type (NEMA). |
| 43 | PowerRating | String | The summary of the device's various power ratings: Voltage, Frequency, and Current. |
| 44 | CreatedDate | String | The date when an entry was first created. |
| 45 | OrgID | String | The unique identifier for the organization. |